Warranty Information

Guarantee is 12 months from purchase date, proof of which will be required for any claim.

  • Assembly: Ensure mains plug is disconnected. Undo clasps, lift off top section, remove contents. Turn container upside down and insert castors. For wet cleaning, fit foam filter; for dry cleaning, fit dust bag or optional cartridge filter. Replace top section and secure with clasps. Insert hose into front inlet and lock. Attach desired nozzle to telescopic tube.
  • Dry Vacuuming: Ensure machine is unplugged. Fit dust bag flange onto inlet stub or slide optional cartridge filter over filter basket. Reposition head and clip in place. Connect hose and attachment. Plug in, switch on. After use, switch off and unplug. Empty bag when 2/3 full. Do not use dust bag for wet or sharp materials.
  • Wet Vacuuming: Ensure machine is unplugged and tank is clean. Remove dust bag, fit foam filter over filter basket. Replace top section. Attach desired nozzle to hose. Ensure switch is off before plugging in. Press switch to 'On'. Do not immerse nozzle completely in liquid. Turn off when motor speed increases (float valve activated). Empty container. Clean and dry machine. Remove foam filter and fit dust bag before dry vacuuming again.
  • Blowing: Push hose into blow connection. Ensure power is off and plug in. Switch on. Clear obstructions. WARNING: If hose is still blocked, turn off and clear manually.

Troubleshooting and error codes

Cleaner will not operate. No power supply.
Faulty power cable, switch or motor.
Check supply.
Check and repair or replace faulty item.
Dust comes from the motor cover. Container full of liquid. Empty container.
Reduced efficiency and increased motor speed/vibration. Dust bag (or cartridge) missing or damaged.
Dust bag full.
Nozzle, hose or container inlet blocked.
Fit or replace dust bag (or cartridge).
Replace dust bag.
Check nozzle, hose and container inlet for blockage.