Brand: SHARP
Category: Audio
Document Type: Parts/Service
Language: EN
Available Languages: EN , ES
Uploaded: Nov. 21, 2025, 8:48 p.m.
Manual Publish Date: 2000
Refer to warranty card for warranty details. No specific warranty period is mentioned in this excerpt.
Refer to the Operation Manual for a complete description of the unit's operation.
| Error | State Code | Description |
|---|---|---|
| [Servo System Error] | 0001 | Cannot detect Pickup-in SW |
| 0002 | DSP access error | |
| [Error during close operation] | 0101 | Open/Close SW not functioning (Low → High) |
| 0103 | Open/Close SW not functioning (High → Low) | |
| [Error during open operation] | 0201 | Open/Close SW not functioning (Low → High) |
| 0203 | Open/Close SW not functioning (High → Low) | |
| [Error during skip operation] | 0302 | Pickup-in SW is not detected |
| 0306 | During Disc 1 search, Open/Close SW or Clamp SW or Disc SW do not change to low. | |
| 0307 | Clamp SW not function (Low → High) | |
| 0308 | Clamp SW not function (High → Low) |