Parts/Service for DSC-RX100M6

Parts/Service for DSC-RX100M6

Brand: SONY

Category: Video Camera

Document Type: Parts/Service

Language: EN

Available Languages: EN , ES

Uploaded: Nov. 21, 2025, 6:21 p.m.

Manual Publish Date: 2018-06-08

Warranty Information

This document is a service manual and does not contain warranty information.

This manual provides information for system and service engineers regarding the maintenance and service of the DSC-RX100M6 camera. It covers troubleshooting, service notes, adjustments, main part replacements, and repair parts lists. Key sections include self-diagnosis functions, error code tables, and specific procedures for handling flexible boards, fine-wire coaxial cables, and flash capacitors. Safety precautions are emphasized throughout.

Troubleshooting and error codes

Repaired by: Block Function Code Detailed Code Symptom/State Correction
C 13 01 Memory card is unformatted or memory card is broken. Format the memory card. Insert a new memory card.
C 32 01 Trouble with hardware Turn power off and turn power on again.
E 41 00 Abnormality of the wireless LAN module or CPU The peripheral circuit of between CPU and wireless LAN module may be faulty. Replace the board that contains this peripheral circuit.
E 41 01 Abnormality of network control device Turn power off and turn power on again.
E 61 00 Difficult to adjust focus (Cannot initialize focus) Turn power off and turn power on again. When this error is not cleared, the focus control signal for the lens block may be faulty. Check whether this error is due to the lens or the board. Replace the faulty lens or board.
E 61 10 Zoom operations fault (Cannot initialize zoom lens) Turn power off and turn power on again. When this error is not cleared, operate the zoom lever and check following items. When zooming is performed, the zoom control signal for the lens block may be faulty. When zooming is not performed, the zoom motor drive circuit may be faulty. Check whether this error is due to the lens or the board. Replace the faulty lens or board.
E 61 30 Reset position detection error on the stepper iris initializing Turn the power on to open lens barrier. Disconnect the battery or power cord, and then connect again. And confirm that the iris blades in lens are working. If iris blades do not work, check the iris motor drive circuit in lens drive block. If iris blades work normally, confirm that they are closing completely and confirm following items. Case of the iris blades do not close normally. Replace the lens block. Case of "E: 61: 30" is appeared and iris blades closed completely. Confirm that communication with lens block is normal. Case of LCD is not displayed normally, check that connection between imager board and main board. Case of LCD is displayed normally, replace the lens block.
E 62 02 Abnormality of IC for steadyshot. Check signal line connections from CPU through steadyshot IC to PITCH/YAW drive. When there is no problem with the connections, replace the board that contains this peripheral circuit.
E 62 10 Shift lens initializing failure Replacement of lens block. *1 If an error occurs again, steadyshot circuit may be faulty. Replace the board that contains this peripheral circuit.
E 62 11 Shift lens overheating (PITCH) Check signal line connections from CPU through steadyshot IC to PITCH/YAW drive. When there is no problem with the connections, check whether this error is due to the lens or the board. Replace the faulty lens or board.
E 62 12 Shift lens overheating (YAW) Check signal line connections from CPU through steadyshot IC to PITCH/YAW drive. When there is no problem with the connections, check whether this error is due to the lens or the board. Replace the faulty lens or board.
E 62 20 Abnormality of thermistor Check signal line connections from CPU through steadyshot IC to PITCH/YAW drive. When there is no problem with the connections, check whether this error is due to the lens or the board. Replace the faulty lens or board.
E 91 01 Abnormality when flash is being charged Checking of flash unit or replacement of flash unit. *2
E 92 00 Battery/Dry cell distinction defect Turn power off and turn power on again.
E 94 00*3 Fault of writing or erasing the internal memory Turn power off and turn power on again.
E 95 00*1 GPS hardware error Check the signal line connection for GPS. When there is no problem with the connections, replace the board that contains this peripheral circuit.
E 95 01 Acceleration sensor hardware error Turn power off and turn power on again. When this error is not cleared, the peripheral circuit of the acceleration sensor may be faulty. Replace the board that contains this peripheral circuit.
E 95 02*1 Electronic compass hardware error (GPS hardware error) The peripheral circuit of the electronic compass may be faulty. Replace the board that contains this peripheral circuit.
Privacy Policy