Manual for RAC-WK0512CMRU

Manual for RAC-WK0512CMRU

Brand: TOSHIBA

Category: Air Conditioner

Document Type: Manual

Language: EN

Available Languages: EN , ES

Uploaded: Nov. 21, 2025, 6:08 p.m.

Manual Publish Date: 2023-08-01

Warranty Information

Product failure due to improper installation is not covered under the warranty.

Normal Sounds

Sound of Rushing Air: Air moved by the fan.

High Pitched Sound: High efficiency compressors may have this sound during cooling cycle.

Trickling Sound: Droplets of water hitting condenser.

Gurgle/Hiss: Refrigerant flowing through evaporator.

Vibration: Unit may vibrate due to poor construction or incorrect installation.

Air Conditioner Features (general)

Operating Conditions: Outdoor temp.: 64~109°F/18~43°C, Indoor temp.: 62~90°F/17~32°C. Relative humidity less than 80%.

Operating Steps

  1. Set temperature to coldest.
  2. Set control to HIGH COOL.
  3. Adjust louver for comfortable airflow.
  4. Adjust temperature once room feels cool.
  5. Ensure airflow is not obstructed.

Air Directional Louvers

Use levers to direct airflow Left/Right, and Up/Down (on some models).

Troubleshooting and error codes

Error CodeDescriptionAction
ASRoom temperature sensor errorUnplug the unit and plug it back in. If error repeats, call for service.
ESEvaporator temperature sensor errorUnplug the unit and plug it back in. If error repeats, call for service.