Start to use your air conditioner

  1. Press the POWER button to start or stop the operation of your appliance.
  2. Press the MODE button to select the operation mode in sequence of Cool Dry, Fan or Heat.
  3. Press the temperature adjustment button to set the desired temperature.
  4. Press the FAN button to choose the desired fan speed in sequence of High, Mid or Low.

Filter Reset

  1. When the Filter Reset indicator light is lit, remove, clean and replace the air filter. See "Cleaning the Air Filter".
  2. Press and release FILTER button after replacing the air filter.

NOTE: After 360 hours of fan operating time, the Filter indicatorlight will turn on. It will remain on for 180 hours or until you press FILTER button. After 180 hours, it will turn off automatically.

IMPORTANT NOTE:

  • When the air conditioner is turned on for the first time after it's plugged in, it will run in the 6th Sense Mode.
  • The air conditioner display shows the setting temperature. Only on standby mode, the display shows the ambient temperature.
  • When changing modes while the air conditioner is operating, the compressor will stop for 3 to 5 minutes before restarting. If a button is pressed during this time, the compressor will not restart for another 3 to 5 minutes.
  • In Cooling or Dry mode, the compressor and condenser fan will stop when the room temperature reaches the set temperature.
  • In Fan Only mode, the temperature can NOT be set. Heating is NOT available for Cooling only air conditioner.
  • Below operation modes can only be set by remote controller.
  • In the event of a power failure, your air conditioner will operate at the previous settings when the power is restored.
  • If the unit is operating in UNLIKELY VERY HUMIDITY environment, water will be collected in the tank inside the unit. The air conditioner will stop once the water tank is full, and the screen will display "E5" to inform you to empty the internal container. There is a plasic tube at the back of the appliance, move the appliance to a safe place, lay down the plastic tube for water drain.

Troubleshooting and error codes

Trouble Analysis
Air conditioner does not operate The power supply cord is unplugged. Plug into a grounded outlet. See "Electrical Requirements."
A household fuse has blown, or a circuit breaker has tripped. Replace the fuse, or reset the circuit breaker. See "Electrical Requirements.”
The On/Off button has not been pressed. Press ON/OFF.
The local power has failed. Wait for power to be restored.
Time-delay fuse or circuit breaker of the wrong capacity is being used. Replace with a time-delay fuse or circuit breaker of the correct capacity. See “Electrical Requirements.”
Air conditioner blows fuses or trips circuit breakers Too many appliances are being used on the same circuit. Unplug or relocate appliances that share the same circuit.
Air conditioner seems to run too much You are trying to restart the air conditioner too soon after turning off air conditioner. Wait at least 3 minutes after turning off air conditioner before trying to restart it.
You have changed modes. Wait at least 3 minutes after turning off air conditioner before trying to restart the appliance.
Air conditioner runs for a short time only, but room is not cool or hot Is there a door or window open? Keep doors and windows closed.
In cooling mode: the air conditioner is in a heavily occupied room, or heat producing appliances are in use in the room. Use exhaust vent fans while cooking or bathing and try not to use heat producing appliances during the hottest part of the day. Local air conditioners are designed as supplemental cooling to local areas within a room. A higher capacity air conditioner may be required, depending on the size of the room being cooled.
In heating mode: the air conditioner is in a very cool room. Local air conditioners are designed as supplemental heating to local areas within a room. A higher capacity air conditioner may be required, depending on the size of the room being heated up.
Display error code Set temperature is close to room temperature. Lower or Higher set temperature. See "Operating mode description".
If the unit display error code E5, it is water full in the unit, you should drain the water, see "Draining the air conditioner". After draining, you can operate the unit.
If the unit display error code El/E2/E3/E6/E7/EA, please contact customer service.
Air conditioner runs, but does not cool/hot The filter is dirty or obstructed by debris. Clean the filter.
Air outlet is blocked. Clear air outlet.
The setting temperature is not compatible. In cooling mode: set temperature is too high. Lower set temperature. In heating mode: set temperature is too low. Higher set temperature
Air conditioner cycles on and off too much The air conditioner is not properly sized for your room. Check the cooling/heating capabilities of your local air conditioner. Local air conditioners are designed as supplemental cooling/heating to local areas within a room.
The filter is dirty or obstructed by debris. Clean the filter.
In cooling mode there is excessive heat or moisture (open container cooking, showers, etc.) in the room. Use a fan to exhaust heat or moisture from the room. Try not to use heat-producing appliances during the hottest part of the day. In heating mode the temperature of the environment is too high. Do not use your air conditioner when the temperature of the environment is too high.
The louvers are blocked. Install the air conditioner in a location where the louvers are free from curtains, blinds, furniture, etc.
The outside temperature is below 18°C. Do not try to operate your air conditioner in the cooling mode when the outside temperature is below 18°C.