Refer to the generator owner's manual for specific warranty information.

STARTING

  1. Ensure two Yamaha EF2000iS or EF2400iS generators are available.
  2. Turn off both generators and unplug any connected electrical devices.
  3. Securely plug the parallel cable set connectors into the generator sockets.
  4. Connect the ground terminals of the parallel cable set to the generator ground terminals.
  5. If the electrical device is grounded, ensure at least one generator frame is grounded.
  6. Start both generators one at a time, confirming proper operation by engine and exhaust noise.
  7. Plug the electrical device's special plug into the parallel cable set socket and turn on the device's power.

STOPPING

  1. Turn off the electrical device and unplug its cable from the parallel cable set socket.
  2. Turn off both generators.
  3. Disconnect the parallel cable set from both generators.

Troubleshooting and error codes

Troubleshooting Section Possible Cause Remedy
Engine Will Not Start Fuel valve is closed. Open the fuel valve.
Fuel is stale or contains water. Replace fuel.
Engine switch is OFF. Turn the engine switch ON.
Engine Stops Suddenly Fuel tank is empty. Refill the fuel tank.
Oil level is low. Add oil.
Air filter is clogged. Clean the air filter.
No Output / Low Output Circuit breaker tripped. Reset the circuit breaker.
Parallel cable set not properly connected. Ensure the parallel cable set is securely connected.