The APEC Water ROES-50 is a reverse osmosis system designed for home use. Operation involves the following key stages:
Problem | Possible Causes and Solutions |
---|---|
Air Bubbles: Lots of Air bubbles in cup or bottle when filling | Normal after initial installation or filter replacement. System will self-purge air. Drain 1-2 tanks of water. |
No Water at Dispensing Faucet | Water supply off, tank valve closed, output line crimped, incorrect installation, low tank pre-charge pressure, ASO connection error. |
Sluggish Flow At Dispensing Faucet | Insufficient water pressure, input water to RO blocked, tank not filled yet, low tank pre-charge pressure. |
Tank Takes Long Time To Fill (does not meet claimed GPD) | Insufficient water pressure, low water temperature. |
Filter Housing Is Leaking | O-ring needs replacement or is not seated correctly. |
TDS (Total Dissolved Solids) Level Reads Higher Than Normal | Forgot to insert membrane, membrane inserted incorrectly, water pressure too low, input source water very high TDS, drain water flow restricted, fluctuating input water TDS. |
There is a leak at the Tank ball valve connection | Insufficient Teflon tape applied during installation. |
System Slow Shut-Off: Drain water runs for hours (6-7 hrs) - but Eventually Stops | Insufficient input water pressure, feed water valve partially blocked, pre-filters partially clogged, RO busy feeding multiple output points. |
System Does Not Shut-Off: Drain water runs all day - and Never Stops | Input pressure way too low. |
RO Makes Humming Noise | Air bubbles trapped in the Check Valve. |
Problem | Possible Causes and Solutions |
---|---|
Air Bubbles: Lots of Air bubbles in cup or bottle when filling | Normal after initial installation or filter replacement. System will self-purge air. Drain 1-2 tanks of water. |
No Water at Dispensing Faucet | Water supply off, tank valve closed, output line crimped, incorrect installation, low tank pre-charge pressure, ASO connection error. |
Sluggish Flow At Dispensing Faucet | Insufficient water pressure, input water to RO blocked, tank not filled yet, low tank pre-charge pressure. |
Tank Takes Long Time To Fill (does not meet claimed GPD) | Insufficient water pressure, low water temperature. |
Filter Housing Is Leaking | O-ring needs replacement or is not seated correctly. |
TDS (Total Dissolved Solids) Level Reads Higher Than Normal | Forgot to insert membrane, membrane inserted incorrectly, water pressure too low, input source water very high TDS, drain water flow restricted, fluctuating input water TDS. |
There is a leak at the Tank ball valve connection | Insufficient Teflon tape applied during installation. |
System Slow Shut-Off: Drain water runs for hours (6-7 hrs) - but Eventually Stops | Insufficient input water pressure, feed water valve partially blocked, pre-filters partially clogged, RO busy feeding multiple output points. |
System Does Not Shut-Off: Drain water runs all day - and Never Stops | Input pressure way too low. |
RO Makes Humming Noise | Air bubbles trapped in the Check Valve. |